ACR Electronics ME406 Series Guide de dépannage Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 33
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
Artex Products / ACR Electronics, Inc. 570-0023 Rev. G
Page 14 of 33
ACK retrofit:
The remote switch 453-0023 and ME406 series ELT cannot be used in conjunction with the ACK
interconnecting cable unless Flat Cable 611-0019 is connected directly with the ACK cable.
This 611-0019 cable is provided as part of the ELT installation pack list or can be ordered as
line item. The cable is installed on the ELT side.
The 611-0018 extender can be discarded since it intended for Ameri-King ELT retrofit.
FLAT CABLE
611-0019
ACK CABLE
(INSIDE AIRCRAFT)
FLAT CABLE
611-0019
611-0019 Wiring
C1
C2
2
5
3
4
4
3
5
2
C1
C2
PIN 2
Vue de la page 13