ACR Electronics SmartReader Plus Spécifications Page 40

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 39
38
For SmartReader Plus Data Loggers
Networking and Remote Communications
Up to 10 SmartReader Plus data loggers can be formed into a network. To do this, run stereo or telephone
cable around the site and connect the loggers anywhere along the cable using ACR’s network Y splitters
(YA-200 for stereo cable or YA-201 for telco cable). If more than 3 data loggers are networked, plug in a power
supply at one end of the network. At the opposite end of the network, connect ACR’s interface cable. If com-
municating directly to a computer, connect the interface cable directly to the computer’s serial port. If com-
municating via modem, connect ACR’s modem adapter (MA-100) between the modem and interface cable.
Order Information
MODEL DESCRIPTION CATALOG #
Stereo Cable Extension Cable - 20’ 31-0024
Telco/Logger Network Cable (Bulk) 31-0044
Telco/Logger Network Connector Install 89-0002
YA-200 Network Y Splitter-Stereo 01-0098
YA-201 Network Y Splitter-Telco 01-0166
USM-C Computer Station Modem 01-0300
USM-R Remote Logger Site Modem 01-0301
MA-100 Modem Adapter for IC-101 Cable 18-0023
IC-101 Computer/Modem to Logger Interface Cable 01-0068
PS-201-NA Network Power Supply (120 Volt) 01-0165
PS-201-EU Network Power Supply (220 Volt) 01-0164
FEATURES
Up to 10 loggers
(80 channels) on
one network
Compatible with
any modem
Automatic data
download
Simple wiring; no
hub required
FEATURES
Up to 8 loggers
(64 channels) on
one network
Compatible with
any modem
Automatic data
download
Simple wiring; no
hub required
For SmartReader Data Loggers
To communicate with a single SmartReader data logger over a modem, use ACR’s modem adapter (MA-100)
and interface cable (IC-101). Connect up to 8 SmartReader data loggers (up to 64 channels) in a network and
communicate with it locally or remotely via modem using ACR’s multi-logger interface module (IC-200).
Order Information
MODEL DESCRIPTION CATALOG #
Stereo Cable Extension Cable - 20’ 31-0024
IC-200-120V 8-Port Network Int. Cable-120V (120 Volt, 60 Hz version) 01-0043
IC-200-220V 8-Port Network Int. Cable-220V (220 Volt, 50 Hz version) 01-0085
IC-200-NPS 8-Port Network Int. Cable-NPS (Requires 5V DC power supply) 01-0065
MA-100 Modem Adapter for IC-101 Cable 18-0023
IC-101 Computer/Modem to Logger Interface Cable 01-0068
IC-101, MA-100
and modem
IC-200
1 SmartReader
Modem
8 SmartReaders
Single Logger Multiple Loggers
Networking and Remote Communications
Vue de la page 39