Reference Guide
IMPORTANT!
SmartReader Plus Data Loggers
Vue de la page 0
1 2 3 4 5 6 ... 116 117

Résumé du contenu

Page 1 - IMPORTANT!

Copyright © 2010 ACR Systems Inc. All Rights Reserved.Reference GuideIMPORTANT!SmartReader Plus Data Loggers

Page 2 - SmartReader Plus Data Loggers

SmartReader Plus Data Loggers1Copyright © 2010 ACR Systems Inc. All Rights Reserved.SECTION 1 SmartReader Plus Data Logger1.1Introduction to SmartR

Page 3 - TRADEMARK NOTICES

SmartReader Plus Data Loggers91Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.18APPENDIX D Typical SmartReader Plus 3 ConnectionDiagramTyp

Page 4 - LIMITED WARRANTY

SmartReader Plus Data Logger92Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.18.2 AC Voltage Transducer SpecificationsVoltage InputSingle ph

Page 5 - Table of Contents

SmartReader Plus Data Loggers93Copyright © 2010 ACR Systems Inc. All Rights Reserved.3588-2-RS:4.4"W x 3.8"D x 4.7"H(112 x 97 x 119mm)

Page 6

SmartReader Plus Data Logger94Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.19APPENDIX E Sample RatesSample Rates 1.19.1 How a Data Logge

Page 7

SmartReader Plus Data Loggers95Copyright © 2010 ACR Systems Inc. All Rights Reserved. 2 sec.0115640 5 sec.155140 8 sec.1234640 20 sec.4232640 1 min.1

Page 8

SmartReader Plus Data Logger96Copyright © 2010 ACR Systems Inc. All Rights Reserved. 0.1 sec.001156 0.2 sec.002353 0.5 sec.005943 1 sec.015926 2 sec.

Page 9

SmartReader Plus Data Loggers97Copyright © 2010 ACR Systems Inc. All Rights Reserved.Table F-5: SmartReader Plus-32K Sample Rate - Five Channels Ena

Page 10 - 1.1.2 Description

SmartReader Plus Data Logger98Copyright © 2010 ACR Systems Inc. All Rights Reserved. 2 hrs.29814400 4 hrs.5975200Table F-7: SmartReader Plus-32K Sam

Page 11 - 1.1.3 Programmed Operation

SmartReader Plus Data Loggers99Copyright © 2010 ACR Systems Inc. All Rights Reserved. 5 min.975730 10 min.1815550 30 min.5523450 1 hr.11123300 2 hrs.

Page 12

SmartReader Plus Data Logger100Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.20APPENDIX F Connecting Multiple LoggersConnecting Multiple

Page 13

SmartReader Plus Data Logger2Copyright © 2010 ACR Systems Inc. All Rights Reserved.long-life lithium battery that will provide years of reliable oper

Page 14 - 1.1.6 Specifications

SmartReader Plus Data Loggers101Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.20.2 Basic NetworkThe Basic Network accommodates a maximum of

Page 15 - Internal Temperature Sensor*

SmartReader Plus Data Logger102Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.20.3 Modular NetworkThe Modular Network accommodates a maximum

Page 16 - 1.1.7 Product Approvals

SmartReader Plus Data Loggers103Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.20.4 Shielded NetworkThe Shielded Network accommodates a maxi

Page 17

SmartReader Plus Data Logger104Copyright © 2010 ACR Systems Inc. All Rights Reserved.1. Slow the baud rate.2. Use the PS-201 Power Supply connected t

Page 18 - 1.2.1 Logger Status

SmartReader Plus Data Loggers105Copyright © 2010 ACR Systems Inc. All Rights Reserved.Index- A -AC Current 91AC Voltage Transducer 33, 91- C -Cali

Page 19

Index106Copyright © 2010 ACR Systems Inc. All Rights Reserved.Thermocouple E Type 44, 47J Type 44, 47K Type 44, 47S Type 44, 47T Type 44, 47Tra

Page 21

ACR Systems Inc.Building 210 - 12960 84th Ave.Surrey, British Columbia, Canada V3W 1K7Telephone: (604) 591-1128North American Toll Free: 1-800-663-

Page 22

SmartReader Plus Data Loggers3Copyright © 2010 ACR Systems Inc. All Rights Reserved.the sample rate the logger begins to average readings before savi

Page 23

SmartReader Plus Data Logger4Copyright © 2010 ACR Systems Inc. All Rights Reserved.must be connected to the data logger.Making External ConnectionsIf

Page 24

SmartReader Plus Data Loggers5Copyright © 2010 ACR Systems Inc. All Rights Reserved.Cold or Humid EnvironmentsMake sure that the environment you will

Page 25

SmartReader Plus Data Logger6Copyright © 2010 ACR Systems Inc. All Rights Reserved.Memory Sizes:ModelReadingsBytes32 KB21,50032 KB128 KB87,000128 KB1

Page 26

SmartReader Plus Data Loggers7Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.1.7 Product ApprovalsMeets Part 15 for Digital Devices of the C

Page 27

SmartReader Plus Data Logger8Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.2SmartReader Plus Software DriverTrendReader software uses a sof

Page 28 - 1.2.2 Logger Channels

SmartReader Plus Data Loggers9Copyright © 2010 ACR Systems Inc. All Rights Reserved.open, thereby allowing you to make changes in other features.NOTE

Page 29

SmartReader Plus Data Logger10Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.2.1.1 Logger SamplingThe sample rate is the frequency with whic

Page 30

All rights reserved. No parts of this work may be reproduced in any form or by any means- graphic, electronic, or mechanical, including photocopying,

Page 31

SmartReader Plus Data Loggers11Copyright © 2010 ACR Systems Inc. All Rights Reserved.*Note that the logger will stop recording (go dormant) when you

Page 32

SmartReader Plus Data Logger12Copyright © 2010 ACR Systems Inc. All Rights Reserved.Full. To set when the logger will start recording click on the S

Page 33 - SmartReader Plus Data Logger

SmartReader Plus Data Loggers13Copyright © 2010 ACR Systems Inc. All Rights Reserved.appears at the right. This will pop up a form allowing you to s

Page 34

SmartReader Plus Data Logger14Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.2.1.3 Logger AlarmsAlarms are used to indicate when any reading

Page 35 - 1.3.2 Setup

SmartReader Plus Data Loggers15Copyright © 2010 ACR Systems Inc. All Rights Reserved.Delay Before First Call1.2.1.3.1The Delay Before the First Call

Page 36 - Other Applications

SmartReader Plus Data Logger16Copyright © 2010 ACR Systems Inc. All Rights Reserved.To set this delay, click on the Delay Between Calls field and ent

Page 37 - 1.4.2 Setup

SmartReader Plus Data Loggers17Copyright © 2010 ACR Systems Inc. All Rights Reserved.To set this delay, click on the Delay After Backup field and ent

Page 38 - 1.4.3 Accessories

SmartReader Plus Data Logger18Copyright © 2010 ACR Systems Inc. All Rights Reserved.Alarm Dialout String1.2.1.3.5The Alarm Dialout String contains th

Page 39 - 1.4.4 Troubleshooting

SmartReader Plus Data Loggers19Copyright © 2010 ACR Systems Inc. All Rights Reserved.For example, if you want to dial a pager number, pause for sever

Page 40 - 1.4.6 Specifications

SmartReader Plus Data Logger20Copyright © 2010 ACR Systems Inc. All Rights Reserved.To set the description, click on the Description field and enter

Page 41

SmartReader Plus is a Registered Trademark of ACR Systems Inc.TRADEMARK NOTICES

Page 42 - 1.5.1 Description

SmartReader Plus Data Loggers21Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.2.2.2 Channel AlarmsThe Alarm subsection shows the high and lo

Page 43

SmartReader Plus Data Logger22Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.2.3 Logger Connection SettingsIf you are using a wireless or RF

Page 44 - 1.5.3 Voltage Channels

SmartReader Plus Data Loggers23Copyright © 2010 ACR Systems Inc. All Rights Reserved.8. Select only the SRPLogger. Click OK.

Page 45 - 1.5.5 Specifications

SmartReader Plus Data Logger24Copyright © 2010 ACR Systems Inc. All Rights Reserved.9. Click on the SRPLogger node.10. Click on the Cable Type field

Page 46 - 1.5.6 Troubleshooting

SmartReader Plus Data Loggers25Copyright © 2010 ACR Systems Inc. All Rights Reserved.Click OK. Block SizeThe Block size you use depends on the buffer

Page 47 - 1.6.1 Description

SmartReader Plus Data Logger26Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.3SmartReader Plus 1 Temperature LoggerThe SmartReader Plus 1 is

Page 48 - 1.6.2 Setup

SmartReader Plus Data Loggers27Copyright © 2010 ACR Systems Inc. All Rights Reserved.Other ApplicationsFor information on how you can monitor resista

Page 49 - 1.6.3 Pressure Calibration

SmartReader Plus Data Logger28Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.4SmartReader Plus 2 Temperature & Relative Humidity LoggerA

Page 50 - 1.6.4 Specifications

SmartReader Plus Data Loggers29Copyright © 2010 ACR Systems Inc. All Rights Reserved.0Internal Temperature451Internal Relative Humidity712External Te

Page 51 - Temperature Logger

SmartReader Plus Data Logger30Copyright © 2010 ACR Systems Inc. All Rights Reserved.Figure 2-2: EH-020A ConnectionThe EH-020A is applicable for meas

Page 52

ACR Systems Inc. warrants the hardware to be free from defects in workmanship andcomponents for one year from the date of purchase, provided they are

Page 53 - 1.8.3 Use

SmartReader Plus Data Loggers31Copyright © 2010 ACR Systems Inc. All Rights Reserved.That is because the body readily gives off heat and moisture tha

Page 54

SmartReader Plus Data Logger32Copyright © 2010 ACR Systems Inc. All Rights Reserved.decrease the speed of response.Chemical Tolerances: Limits for di

Page 55 - 1.8.5 Manual Calibration

SmartReader Plus Data Loggers33Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.5SmartReader Plus 3 Current, Voltage and Temperature LoggerThe

Page 56 - 1.9.2 Setup

SmartReader Plus Data Logger34Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.5.2 Setup to Measure CurrentThe procedure for setting up your S

Page 57 - 1.9.4 Specifications

SmartReader Plus Data Loggers35Copyright © 2010 ACR Systems Inc. All Rights Reserved.7Current 464A60FL / A65FLSwitchRangeEquation50.5 to 5 A63252.5 t

Page 58 - 1.9.5 Manual Calibration

SmartReader Plus Data Logger36Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.5.4 Current Probes and AccessoriesEach SmartReader Plus 3 has f

Page 59 - 1.10.2 Setup

SmartReader Plus Data Loggers37Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.5.6 TroubleshootingThe SmartReader Plus 3 seems to give wrong

Page 60

SmartReader Plus Data Logger38Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.6SmartReader Plus 4 Pressure, Temperature and RH LoggerThe Smar

Page 61

SmartReader Plus Data Loggers39Copyright © 2010 ACR Systems Inc. All Rights Reserved.· The Low Pressure Model. This model has an internal pressure c

Page 62

SmartReader Plus Data Logger40Copyright © 2010 ACR Systems Inc. All Rights Reserved.and humidity channels. To connect the EH-020A probe to your Smar

Page 63

IContentsCopyright © 2010 ACR Systems Inc. All Rights Reserved.Table of ContentsSection I SmartReader Plus Data Logger 1...

Page 64

SmartReader Plus Data Loggers41Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.6.4 SpecificationsThe following specifications apply to the pr

Page 65

SmartReader Plus Data Logger42Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.7SmartReader Plus 4 Low Pressure Differential andTemperature Lo

Page 66

SmartReader Plus Data Loggers43Copyright © 2010 ACR Systems Inc. All Rights Reserved.TrendReader guide for more information.)5. Save the new setup.1.

Page 67 - 1.10.6 Specifications

SmartReader Plus Data Logger44Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.8SmartReader Plus 5 Thermocouple LoggerThe SmartReader Plus 5 T

Page 68

SmartReader Plus Data Loggers45Copyright © 2010 ACR Systems Inc. All Rights Reserved.other (positive) wire to the "+" terminal. The follow

Page 69 - 1.11.2 Setup and Use

SmartReader Plus Data Logger46Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.8.4 SpecificationsAccuracy: ±0.5% of range plus resolutionTherm

Page 70

SmartReader Plus Data Loggers47Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.9SmartReader Plus 6 Thermocouple LoggerThe SmartReader Plus 6

Page 71 - 1.12.1 Description

SmartReader Plus Data Logger48Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.9.3 Use1. Connect a J, K, T, S or E type thermocouple to one or

Page 72 - 1.12.4 Specifications

SmartReader Plus Data Loggers49Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.9.5 Manual CalibrationA simple way to manually adjust the cali

Page 73

SmartReader Plus Data Logger50Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.10SmartReader Plus 7 Process Signal LoggerA multi-channel, mult

Page 74 - 1.13.2 Setup

SmartReader Plus Data LoggersIICopyright © 2010 ACR Systems Inc. All Rights Reserved...

Page 75

SmartReader Plus Data Loggers51Copyright © 2010 ACR Systems Inc. All Rights Reserved.2. Determine what sensors, transducers or transmitters you need

Page 76 - 1.14.1 Description

SmartReader Plus Data Logger52Copyright © 2010 ACR Systems Inc. All Rights Reserved.Avoiding Ground LoopsTake special care to avoid ground loop probl

Page 77 - 1.14.3 Accessories

SmartReader Plus Data Loggers53Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.10.4 Customizing Input RangesThe standard input ranges on the

Page 78 - (-40 to 158°F)

SmartReader Plus Data Logger54Copyright © 2010 ACR Systems Inc. All Rights Reserved.Since you will not always be able to get the exact resistor value

Page 79

SmartReader Plus Data Loggers55Copyright © 2010 ACR Systems Inc. All Rights Reserved.marked "10k" must be 10,000 ohms ±1% or better.Figure

Page 80 - Monitoring Resistance

SmartReader Plus Data Logger56Copyright © 2010 ACR Systems Inc. All Rights Reserved.power rating greater or equal to 0.1 watts. Therefore, a quarter

Page 81

SmartReader Plus Data Loggers57Copyright © 2010 ACR Systems Inc. All Rights Reserved.Orange3Yellow4Green5Blue6Violet7Grey8White9Gold5%JSilver10%KNone

Page 82 - Calibration

SmartReader Plus Data Logger58Copyright © 2010 ACR Systems Inc. All Rights Reserved.impedance. This simply refers to how much resistance your instru

Page 83

SmartReader Plus Data Loggers59Copyright © 2010 ACR Systems Inc. All Rights Reserved.Overload Protection: Voltage channels: ±40V Current channels: ±7

Page 84

SmartReader Plus Data Logger60Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.11SmartReader Plus 8 Eight-Channel Temperature LoggerThe SmartR

Page 85 - H - bL) - 1)

IIIContentsCopyright © 2010 ACR Systems Inc. All Rights Reserved...

Page 86

SmartReader Plus Data Loggers61Copyright © 2010 ACR Systems Inc. All Rights Reserved.any Common terminal.Figure 8-2: Connecting External Temperature

Page 87 - L - 145 x bH) / 296

SmartReader Plus Data Logger62Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.12SmartReader Plus 9 Pulse LoggerThe SmartReader Plus 9 is a tw

Page 88 - Thermistor Temperature

SmartReader Plus Data Loggers63Copyright © 2010 ACR Systems Inc. All Rights Reserved.instead of the logger supplying the voltage potential, the logge

Page 89 - 1.17.4 Setup and Use

SmartReader Plus Data Logger64Copyright © 2010 ACR Systems Inc. All Rights Reserved.>4.0K for Vin>5VMin. Pulse Width50% Duty Cycle: Slow input:

Page 90 - 1.17.5 Specifications

SmartReader Plus Data Loggers65Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.13SmartReader Plus 10 RTD Temperature LoggerThe SmartReader Pl

Page 91

SmartReader Plus Data Logger66Copyright © 2010 ACR Systems Inc. All Rights Reserved.For the internal channel, use equation 45For the 100 ohm probes,

Page 92

SmartReader Plus Data Loggers67Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.14Conservation Logger Temperature, RH and 5V Input LoggerThe C

Page 93

SmartReader Plus Data Logger68Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.14.2 SetupMake sure to enable each channel you want to use. If

Page 94

SmartReader Plus Data Loggers69Copyright © 2010 ACR Systems Inc. All Rights Reserved.Interchangeable replacement RH sensors for loggers are available

Page 95

SmartReader Plus Data Logger70Copyright © 2010 ACR Systems Inc. All Rights Reserved.Range: 0 to 95% RHAccuracy: ±3% RH from 10 to 90% (-20 to 40°C [-

Page 96

SmartReader Plus Data LoggersIVCopyright © 2010 ACR Systems Inc. All Rights Reserved.Index105

Page 97

SmartReader Plus Data Loggers71Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.15APPENDIX A Monitoring Resistance and Switch StatusMonitori

Page 98

SmartReader Plus Data Logger72Copyright © 2010 ACR Systems Inc. All Rights Reserved.TrendReader software. Figure A-1: Monitoring Switch StatusWhen m

Page 99 - 1.17.7 Custom Probes

SmartReader Plus Data Loggers73Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.16APPENDIX B Temperature and Relative Humidity CalibrationTe

Page 100 - Connection Diagram

SmartReader Plus Data Logger74Copyright © 2010 ACR Systems Inc. All Rights Reserved.4. Insert the thermometer and the thermistor probes into the buck

Page 101

SmartReader Plus Data Loggers75Copyright © 2010 ACR Systems Inc. All Rights Reserved.place in refrigeration chamber of known temperature.For 25°C, pl

Page 102

SmartReader Plus Data Logger76Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.16.3 Relative Humidity CalibrationIf you want to confirm the ca

Page 103 - Sample Rates

SmartReader Plus Data Loggers77Copyright © 2010 ACR Systems Inc. All Rights Reserved.13. If the results are satisfactory, save the calibration change

Page 104

SmartReader Plus Data Logger78Copyright © 2010 ACR Systems Inc. All Rights Reserved.4. Place the logger with sensor or EH-020A module into the jar co

Page 105

SmartReader Plus Data Loggers79Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.17APPENDIX C Thermistor Temperature ProbesThermistor Tempera

Page 106

SmartReader Plus Data Logger80Copyright © 2010 ACR Systems Inc. All Rights Reserved.ranges in order to maximize measurement accuracy and resolution.

Page 107

WELCOMECongratulations on your purchase of a SmartReader Plus data logger. We are confidentthat you will find it to be a most valuable and useful too

Page 108

SmartReader Plus Data Loggers81Copyright © 2010 ACR Systems Inc. All Rights Reserved.Extending Cable LengthsIf you find the standard length of your E

Page 109 - Connecting Multiple Loggers

SmartReader Plus Data Logger82Copyright © 2010 ACR Systems Inc. All Rights Reserved.red and black leads are stripped and tinned.Figure C-1: ET-016 P

Page 110 - 1.20.2 Basic Network

SmartReader Plus Data Loggers83Copyright © 2010 ACR Systems Inc. All Rights Reserved.and black leads are stripped and tinned.Figure C-2: ET-004 Prob

Page 111 - 1.20.3 Modular Network

SmartReader Plus Data Logger84Copyright © 2010 ACR Systems Inc. All Rights Reserved.wire; red and white leads are stripped and tinned.Figure C-3: ET

Page 112 - 1.20.4 Shielded Network

SmartReader Plus Data Loggers85Copyright © 2010 ACR Systems Inc. All Rights Reserved.tinned.Figure C-4: ET-086 Probe Resolution1.17.6 Resistance vs.

Page 113

SmartReader Plus Data Logger86Copyright © 2010 ACR Systems Inc. All Rights Reserved.Table C-1: Temperature-Resistance Values for ET Series Probes

Page 114

SmartReader Plus Data Loggers87Copyright © 2010 ACR Systems Inc. All Rights Reserved.

Page 115

SmartReader Plus Data Logger88Copyright © 2010 ACR Systems Inc. All Rights Reserved.

Page 116

SmartReader Plus Data Loggers89Copyright © 2010 ACR Systems Inc. All Rights Reserved.

Page 117

SmartReader Plus Data Logger90Copyright © 2010 ACR Systems Inc. All Rights Reserved.1.17.7 Custom ProbesObtaining thermistors through specialty suppl