Y1-03-0158G 6
bulkhead, use a cable outlet (available at marine hardware stores). Wire
should be supported where necessary by the use of cable straps.
The location selected must be sufficiently rigid to support the weight of
the total installation. Also consider surrounding hazards such as
equipment movement, hatches being opened, accidental covering,
personnel traffic, etc.
Depending on the location selected, your light will need 1/4” diameter
stainless steel bolts, nuts, and washers. If the mounting area is robust
enough, pan-head lag screws may be used. If the surface area can be
reached from the underside, bolting with lock nuts and washers should
be used.
When mounting, be sure that the unit is able to rotate 360° without
hitting any obstructions. Refer to wiring section for additional
information.
SECTION 3 - INSTALLATION
Wiring
The RCL-75 has two wiring requirements:
1.) Connect the remote control Point Pad™ to the light
2.) Connect the light to 12-volt power with 15 amp rated wiring. The
light works best with 13.5 volts.
Figure 2
Figure 3