ACR Electronics L-32 RCL - REV C Spécifications Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
Y1-03-0141F 6
Additional Point Pads™ (up to three (3) pads) may be used with one (1) Master
Controller. A standard "T" connector or RG-59 television type "splitter" is used for each
additional Point Pad (see Figure 2). Limit the total length of all coax cable used to 300
feet.
The URP-102 Point Pad™ is backwards compatible with all RCL-100/50 searchlights
and with the URC-101 Master Controller.
CAUTION: The URP-102 Point Pad™ is not recommended for use with the first
generation URC-100 Master Controllers.
Figure 2- Point Pad™ Connection Block Diagram
URP-102
Point Pad
URP-102
Point Pad
URC-102
Master
Controller Unit
URC-102
Master
Controller Unit
Power
Source
Power
Source
RG-59 Coaxial Cable
RG-59 Coaxial Cable
RG-59 Coaxial Cable
RG-59 Coaxial Cable
Fuse
Fuse
“T” Conn.
or Splitter
Single Point Pad
Multiple Point Pads
Vue de la page 6