Acr-electronics PLB-350C Manuel d'utilisateur Page 27

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 33
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 26
Y1-03-0244B 27
This message appears if Self-Test has passed, but the battery is low. Take
the beacon to an authorized Service Center for a battery replacement.
NOTES regarding Self-Test logic:
1.) When one of the tests fail, the system bypasses the remaining tests
and goes to SELF-TEST FAIL
2.) The only exception to #1 is that if the battery fails, the other tests are
still performed. The system will tell the user if there are other system
failures by flashing SELF-TEST FAIL. If there are no failures other than
battery life, the system flashes SELF-TEST PASS, then BATT LOW.